Most large aircraft are fitted with an Auxiliary Power Unit
(APU) supplying a phase to neutral 115VAC 400Hz source. The APU is used primarily to start the
aircraft engines, but is also used to run accessories on the plane while
passengers are on board and for preflight checks by the crew when the aircraft
has left the gate.
The reason 400Hz was chosen over the traditional 50/60Hz is
because of weight. A 400Hz generator is
much lighter, thus saving fuel, and the need to support a heavier unit making
the airframe lighter.
MIL-STD-704F is the specification that covers Aircraft
Electrical Power Characteristics for US military aircraft, and covers in detail
all aspects of the requirements.
If an aircraft is being serviced on the ground, it is more
convenient and safer not to have either the main engines or the APU
running. In this case an external 400Hz
generator or Ground Power Unit is usually available. Often diagnostic equipment is not required to
meet the full flight specifications and for cost purposes a regular industrial
power supply can be chosen.
TDK-Lambda is often asked if one of our AC-DC industrial power
supplies will work off 400Hz input, usually the answer is “yes”; the following
explains why:
For low wattage power supplies (50W or less), the input
circuit is a simple full wave bridge rectifier.
Simple full wave
bridge rectifier circuit
The AC voltage is filtered and then full wave rectified into
high voltage DC. With a 60Hz input, the
ripple voltage on the bulk cap is 120Hz. With a 400Hz input, the ripple voltage
is 800Hz (hence smaller), having no impact on the power supply performance.For power supplies greater than 50W, most AC-DC power supplies have active Power Factor Correction circuitry. Simply put, a boost converter is used to reduce the input harmonic currents by changing their shape to appear more sinusoidal - as if the load were resistive.
Boost Converter
The Boost FET in the above circuit is driven by a control IC. The IC regulates the converter receiving feedback
from three sources: the 100-120Hz rectified input voltage (Point “A”), the
inductor current and the DC voltage across the bulk capacitor.
Although most PFC circuits will operate from a 400Hz input,
the wave shape of the current harmonics is slightly degraded due to distortion at
Point “A” (now an 800Hz waveform). This,
however, is usually acceptable for ground based equipment.
Simplified Diagram
Showing “Y” cap locations
To reduce high frequency radiated and conducted noise, power
supply input filters use special “Y” decoupling capacitors connected from the
Line & Neutral to Chassis (Earth) ground.
In addition to high frequency current, these Y capacitors also provide a
path for 50/60Hz current. The maximum
value of this “earth leakage” current is dictated by the safety agencies like
UL, particularly for equipment that is plugged into a regular wall socket found
in an office (for example). For large
pieces of equipment that is hard wired to an AC source, the limits are much
higher.
With a 400Hz input, the earth leakage current is significantly
increased through the “Y” (input to ground) capacitors as that current is
directly proportional to the input frequency, I = V x 2πfC.
However,
ground based equipment running off 400Hz generators falls into the hard wired
category, so this is not normally a problem.
One last note; although commercial power supplies are safety certified to the Information Technology Equipment standard IEC 60950-1, testing for the report is usually conducted with a 50-60Hz input. Most ground based aircraft systems do not fall under IEC 60950-1 but using a power supply certified to that standard means the product has been rigorously tested.